CLIVETEDGE Pro / WiSAN-PMP 1 S 7.1 IBH
The CLIVET EDGE Pro / WiSAN-PMP 1 S 7.1 IBH is an air-to-water heat pump with a SCOP of 4.76 (35 °C) and a sound power level of 48 dB(A). Under permitted development the limit is 37 dB(A) measured 1 m in front of the centre of a neighbour’s habitable-room door or window. Free-standing, the indicative minimum distance is 1.4 m; against a wall 2.0 m.1
Key figures
Rules in the UK
Minimum distance to your neighbour
MCS 020(a) (England, permitted development since 29 May 2025)2 · 1 m in front of the centre of a neighbour’s habitable-room door or window
Indicative calculation (hemispherical, no barriers). Not a substitute for an MCS 020 assessment.
Boiler Upgrade Scheme
Check conditions£7,500 – £9,0003Fixed grant (England & Wales)
Fixed grant in England and Wales, deducted from your installer’s quote. £9,000 when replacing oil or LPG off the gas grid (until March 2027). Scotland: Home Energy Scotland grant instead.4,5
- Must be MCS-certified (product and installer). Check the Ofgem product eligibility list.
- Rated output 14 kW; the scheme covers systems up to 45 kW.
- SCOP at 55 °C: 3.88. The installed system needs a SCOP of at least 2.8 (MCS calculation).
Technical specifications
| General | |
|---|---|
| Type | Air-to-water1 |
| Compressors | 11 |
| Capacity control | digital scroll1 |
| Performance | |
| Rated output 35 °C | 14 kW1 |
| Rated output 55 °C | 14 kW1 |
| Efficiency | |
| SCOP (35 °C) | 4.761 |
| SCOP (55 °C) | 3.881 |
| Seasonal efficiency ηs 35 °C | 188 %1 |
| Seasonal efficiency ηs 55 °C | 152 %1 |
| COP A7/W35 | 4.71 |
| COP A2/W35 | 3.71 |
| COP A-7/W35 | 2.711 |
| Noise | |
| Outdoor unit sound power | 48 dB(A)1 |
| Indoor unit sound power | 41 dB(A)1 |
| Refrigerant | |
| Refrigerant | R2901 |
| Refrigerant charge | 1.5 kg1 |
| Electrical | |
| Max. power input | 9.6 kW1 |
| Connectivity & smart | |
| SG Ready | Yes1 |
Frequently asked questions
Can I install the CLIVET EDGE Pro / WiSAN-PMP 1 S 7.1 IBH without planning permission?
Under MCS 020(a) (England, permitted development since 29 May 2025) the unit must not exceed 37 dB(A) 1 m in front of the centre of a neighbour’s habitable-room door or window. With a sound power of 48 dB(A) that indicatively means 1.4 m free-standing, 2.0 m against a wall or 2.8 m in a corner. Your MCS installer must confirm this.1
How much Boiler Upgrade Scheme grant can you get for the CLIVET EDGE Pro / WiSAN-PMP 1 S 7.1 IBH?
£7,500 in England and Wales, provided the product and installer are MCS-certified (£9,000 when replacing oil or LPG off the gas grid, until March 2027). The installer applies and deducts the grant from your quote.1
Which refrigerant does the CLIVET EDGE Pro / WiSAN-PMP 1 S 7.1 IBH use?
The CLIVET EDGE Pro / WiSAN-PMP 1 S 7.1 IBH uses R290.1
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
- MCS 020(a) (England, permitted development since 29 May 2025)
- Boiler Upgrade Scheme: what you can get — GOV.UK · accessed 27 Sept 2026
- Boiler Upgrade Scheme: guidance for installers (V5) — Ofgem · accessed 27 Sept 2026