Heat pumps · UK

POWER WORLD MACHINERY EQUIPMENTPW16-DKXLRE1-H8

The POWER WORLD MACHINERY EQUIPMENT PW16-DKXLRE1-H8 is an air-to-water heat pump with a SCOP of 5.17 (35 °C) and a sound power level of 59 dB(A). Under permitted development the limit is 37 dB(A) measured 1 m in front of the centre of a neighbour’s habitable-room door or window. Free-standing, the indicative minimum distance is 5.0 m; against a wall 7.1 m.1

Last updated: Technical specifications Rules in the UK

Key figures

SCOP (35 °C)
5.171

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Outdoor unit sound power
59dB(A)1
Official source
Refrigerant
R2901
Official source
Rated output 35 °C
15.93kW1
Official source
Rated output 55 °C
15.43kW1
Official source
UK

Rules in the UK

Minimum distance to your neighbour

MCS 020(a) (England, permitted development since 29 May 2025)2 · 1 m in front of the centre of a neighbour’s habitable-room door or window

Permitted development (MCS 020(a)) ≤ 37 dB(A) · LAeq,5min
Free-standing 5 m
Against wall 7.1 m
In corner 10 m

Indicative calculation (hemispherical, no barriers). Not a substitute for an MCS 020 assessment.

Boiler Upgrade Scheme

Check conditions

£7,500 – £9,0003Fixed grant (England & Wales)

Fixed grant in England and Wales, deducted from your installer’s quote. £9,000 when replacing oil or LPG off the gas grid (until March 2027). Scotland: Home Energy Scotland grant instead.4,5

  • Must be MCS-certified (product and installer). Check the Ofgem product eligibility list.
  • Rated output 15.93 kW; the scheme covers systems up to 45 kW.
  • SCOP at 55 °C: 3.87. The installed system needs a SCOP of at least 2.8 (MCS calculation).
Heat pump grants in the UK explained →

Technical specifications

General
Type Air-to-water1
Compressors 11
Capacity control drehzahlregelung1
Performance
Rated output 35 °C 15.93 kW1
Rated output 55 °C 15.43 kW1
Efficiency
SCOP (35 °C) 5.171
SCOP (55 °C) 3.871
Seasonal efficiency ηs 35 °C 203.7 %1
Seasonal efficiency ηs 55 °C 151.6 %1
COP A7/W35 4.841
COP A2/W35 5.081
COP A-7/W35 2.981
Noise
Outdoor unit sound power 59 dB(A)1
Indoor unit sound power 44 dB(A)1
Refrigerant
Refrigerant R2901
Refrigerant charge 1.7 kg1
Electrical
Max. power input 5.42 kW1
Connectivity & smart
SG Ready Yes1

Frequently asked questions

Can I install the POWER WORLD MACHINERY EQUIPMENT PW16-DKXLRE1-H8 without planning permission?

Under MCS 020(a) (England, permitted development since 29 May 2025) the unit must not exceed 37 dB(A) 1 m in front of the centre of a neighbour’s habitable-room door or window. With a sound power of 59 dB(A) that indicatively means 5.0 m free-standing, 7.1 m against a wall or 10.0 m in a corner. Your MCS installer must confirm this.1

How much Boiler Upgrade Scheme grant can you get for the POWER WORLD MACHINERY EQUIPMENT PW16-DKXLRE1-H8?

£7,500 in England and Wales, provided the product and installer are MCS-certified (£9,000 when replacing oil or LPG off the gas grid, until March 2027). The installer applies and deducts the grant from your quote.1

Which refrigerant does the POWER WORLD MACHINERY EQUIPMENT PW16-DKXLRE1-H8 use?

The POWER WORLD MACHINERY EQUIPMENT PW16-DKXLRE1-H8 uses R290.1

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. MCS 020(a) (England, permitted development since 29 May 2025)
  3. Boiler Upgrade Scheme: what you can get — GOV.UK · accessed 27 Sept 2026
  4. Boiler Upgrade Scheme: guidance for installers (V5) — Ofgem · accessed 27 Sept 2026
  5. Boiler Upgrade Scheme product eligibility — Ofgem · accessed 27 Sept 2026