Heat pumps · Compare

LG Electronics Deutschland THERMA V HM071HF + HN1616HY vs Panasonic Deutschland Aquarea [WH-ADC0309K3E5AN / WH-UDZ07KE5]

SCOP (35 °C): LG Electronics Deutschland THERMA V HM071HF + HN1616HY 5.2, Panasonic Deutschland Aquarea [WH-ADC0309K3E5AN / WH-UDZ07KE5] 4.9. The LG Electronics Deutschland THERMA V HM071HF + HN1616HY is better on 8 of 13 comparable points.

Who wins where

  • LG Electronics Deutschland THERMA V HM071HF + HN1616HY
  • Panasonic Deutschland Aquarea [WH-ADC0309K3E5AN / WH-UDZ07KE5]
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: LG Electronics Deutschland THERMA V HM071HF + HN1616HY 23, Panasonic Deutschland Aquarea [WH-ADC0309K3E5AN / WH-UDZ07KE5] 23; Efficiency: LG Electronics Deutschland THERMA V HM071HF + HN1616HY 57, Panasonic Deutschland Aquarea [WH-ADC0309K3E5AN / WH-UDZ07KE5] 50; Noise: LG Electronics Deutschland THERMA V HM071HF + HN1616HY 69, Panasonic Deutschland Aquarea [WH-ADC0309K3E5AN / WH-UDZ07KE5] 28; Refrigerant: LG Electronics Deutschland THERMA V HM071HF + HN1616HY 85, Panasonic Deutschland Aquarea [WH-ADC0309K3E5AN / WH-UDZ07KE5] 53; Connectivity & smart: LG Electronics Deutschland THERMA V HM071HF + HN1616HY 50, Panasonic Deutschland Aquarea [WH-ADC0309K3E5AN / WH-UDZ07KE5] 50

Biggest differences

FactTHERMA V HM071HF + HN1616HYAquarea [WH-ADC0309K3E5AN / WH-UDZ07KE5]
Refrigerant charge0.9 kg1.3 kg
COP A2/W353.85.03
Outdoor unit sound power49 dB(A)56 dB(A)
Seasonal efficiency ηs 35 °C207 %193 %
SCOP (55 °C)3.853.62
Seasonal efficiency ηs 55 °C151 %142 %
All specifications ↓

Score per area = position (0–100) relative to all 1000 models in this category; higher is better.

Technical specifications LG Electronics DeutschlandTHERMA V HM071HF + HN1616HY Panasonic DeutschlandAquarea [WH-ADC0309K3E5AN / WH-UDZ07KE5]
Grants & market
Boiler Upgrade Scheme £7,500 – £9,000£7,500 – £9,000
Performance
Rated output 35 °C 7 kW 1 7 kW 1
Rated output 55 °C 7 kW 1 7 kW 1
Efficiency
SCOP (35 °C) 5.2 ✓ 1 4.9 1
SCOP (55 °C) 3.85 ✓ 1 3.62 1
Seasonal efficiency ηs 35 °C 207 % ✓ 1 193 % 1
Seasonal efficiency ηs 55 °C 151 % ✓ 1 142 % 1
COP A7/W35 5 ✓ 1 4.86 1
COP A2/W35 3.8 1 5.03 ✓ 1
COP A-7/W35 2.8 1 2.8 1
SEER (cooling) – 5.43 1
Noise
Outdoor unit sound power 49 dB(A) ✓ 1 56 dB(A) 1
Indoor unit sound power 39 dB(A) ✓ 1 41 dB(A) 1
Refrigerant
Refrigerant R290 1 R32 1
Refrigerant charge 0.9 kg ✓ 1 1.3 kg 1
Electrical
Max. power input 2.5 kW 1 3.58 kW 1
Connectivity & smart
SG Ready Yes 1 Yes 1

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026